Climacoustic HVAC/OEM Roll (Unfaced)

HVAC Insulation RollClimacoustic® HVAC/OEM Roll (Unfaced) is a thermal and acoustical insulation blanket made from highly resilient, inorganic glass fibers bonded with ECOSE® Technology.

Application

Climacoustic HVAC/OEM roll (unfaced) is used as external insulation on commercial and residential heating or air conditioning ducts.

It is suitable for the exterior of rectangular or round sheet metal ducts and spaces or surfaces where temperature and condensation must be controlled.

Proven Performance

  • Preferred by professional installers concerned with quality, appearance and  productivity.
  • Excellent acoustical properties reduce sound transmission in the home when  properly installed in walls, ceiling and floor systems.

Durability

  • Climacoustic HVAC/OEM roll is odourless, rot proof, non-hygroscopic, do not sustain vermin and will not encourage the growth of fungi, mould or bacteria.

Superior Handling

  • Highly resilient insulation recovers quickly to full thickness for a snug fit and superior finished aesthetics.
  • Consistent quality materials feel good, cut easily and install fast. 
  • Low dust for easier handling and increased productivity.

Convenient Packaging, Easier Handling

  • Climacoustic HVAC/OEM roll is packaged in a strong, white poly bag that offers excellent protection from abuse, dust and moisture.
  • Climacoustic HVAC/OEM Roll packages feature easy to follow installation instructions.
  • MasterBag batt units (containing multiple packs) ensure reduced handling costs with improved compression – more square metres per bag, more square metres per truck load, fewer trips to the job site and less warehouse space for storage.

Superior Service and Support

  • Knauf Insulation is totally focused on providing first class customer service, producing high quality product and ‘on time in full’ deliveries. 
  • Knauf Insulation recognises the need to establish, develop and support a professional network of distributors and re-sellers in order to service a growing insulation market. 
  • Knauf Insulation is committed to providing a comprehensive range of relevant  literature and web-based technical information to support specifiers and consumers.

Climacoustic HVAC/OEM Roll Unfaced 32kg/m³

E-Code
Density
kg/m³
R-Value (m²K/W) Thickness
(mm)
Width (mm) Length (mm) $/m²
450920 32 1.6 50 1,200 15,000 7.06
450918 32 2.3 75 1,200 10,000 10.56

Custom Products: For items not listed, please contact your Knauf Insulation Sales Representative. All custom product requests require approval, regardless of whether the product has previously been produced. Special pricing and minimum order quantities will apply.

Pricing is GST Exclusive.

  


Climacoustic HVAC/OEM Roll Unfaced 24kg/m³

SAP Code Density
kg/m³
R-Value (m²K/W) Thickness
(mm)
Width (mm) Length (mm) $/m²
450922 24 1.5 50 1,200 18,000 5.50
450921 24 2.0 75 1,200 10,000 8.22

Custom Products: For items not listed, please contact your Knauf Insulation Sales Representative. All custom product requests require approval, regardless of whether the product has previously been produced. Special pricing and minimum order quantities will apply.

Pricing is GST Exclusive.

Specification Compliance

• AS/NZS 4859.1: 2002 Materials used in the Thermal Insulation of Buildings and comply with the Building Code of Australia (BCA) requirements.

Thermal Conductivity
• ASTM C 518

Thermal Resistance
• ASTM C 653

Specification Guide

The HVAC insulation shall be Climacoustic HVAC/OEM Roll *kg/m3, *mm thick, AS/NZS 4859.1:2002 compliant. The product will be non-combustible, CFC/HCHC free, zero ODP & GWP, glasswool insulation with high post-consumer recycled glass content and with ECOSE® Technology. It will be manufactured under Quality Assurance Standards ISO 9001:2008 and ISO 14001:2004 by Knauf Insulation and shall be installed in accrodance with the instructions issued by them. 

*architect to insert details of product used. 

Bio-solubility

The formulation used for Climacoustic insulation has been independently assessed to meet the requirements of the stringent Note Q standard (and is therefore consistent with the highest Australian and New Zealand industry standards), and also assessed by Knauf Insulation against the criteria of the Australian Safety and Compensation Council ASCC Approved Criteria for Classifying Hazardous Substances [NOHSC: 1008 3rd Edition]. As a result of this assessment, Climacoustic insulation is not classified as hazardous according to the NOHSC criteria.

Technical Data

Water Vapour Absorption (ASTM C 1104)
• Less than 5% by weight.

Corrosion Resistance (ASTM C 665)
• No greater than sterile cotton.

Microbial Growth (ASTM C 1338)
• Does not support microbial growth.

Fire Resistance (ASTM E 136)
• Non-combustible.

Specification Guide

The HVAC insulation shall be Climacoustic HVAC/OEM Roll *kg/m3, *mm thick, AS/NZS 4859.1:2002 compliant. The product will be non-combustible, CFC/HCHC free, zero ODP & GWP, glasswool insulation with high post-consumer recycled glass content and with ECOSE® Technology. It will be manufactured under Quality Assurance Standards ISO 9001:2008 and ISO 14001:2004 by Knauf Insulation and shall be installed in accrodance with the instructions issued by them. 

*architect to insert details of product used. 

Climacoustic® HVAC/OEM Roll (Unfaced) Datasheet